Nordic Semiconductor /nrf5340_application /CLOCK_NS /HFCLK192MSTAT

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as HFCLK192MSTAT

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (HFINT)SRC 0 (NotRunning)ALWAYSRUNNING 0 (NotRunning)STATE

SRC=HFINT, STATE=NotRunning, ALWAYSRUNNING=NotRunning

Description

Status indicating which HFCLK192M source is running

Fields

SRC

Active clock source

0 (HFINT): Clock source: HFINT - on-chip oscillator

1 (HFXO): Clock source: HFXO - derived from external 32 MHz crystal oscillator

ALWAYSRUNNING

ALWAYSRUN activated

0 (NotRunning): Automatic clock control enabled

1 (Running): Oscillator is always running

STATE

HFCLK192M state

0 (NotRunning): HFCLK192M not running

1 (Running): HFCLK192M running

Links

() ()